Home »
Laboratory Equipments » Muffle Furnace Rectangular
Muffle Furnace Rectangular "altis"
Light weight with ceramic fibre wool
insulation (instead of Brick insulation). The outer casing is made of double
walled thick P.C.R.C. Sheet, duly painted. Heating elements are made of
KANTHAL "A-1" wire and backed by high temperature cerwool
insulation, which avoids loss of energy. Temperature is controlled through
Digital Temperature Indicator- cum-controller. To work on 220/230 volts or
400/440 volts A.C. Maximum Temp. is 10000C and working temp 9000C. For
models of higher temperature the maximum temp. is 12000C and working temp.
11500C.
 |
Muffle Size |
Rating |
(a) 250 x 100 x 100 mm |
1.0 KW |
(b) 250 x 125 x 125 mm |
2.0 KW |
(c) 300 x 125 x 125 mm |
2.5 KW |
(d) 300 x 150 x 150 mm |
3.5 KW |
(e) 300 x 200 x 200 mm |
4.0 KW |
(f) 350 x 175 x 125 mm |
4.0 KW |
(g) 375 x 175 x 175 mm |
4.5 KW |
(h) 325 x 150 x 175 mm |
4.5 KW |
(i) 475 x 175 x 175 mm |
5.0 KW |
|
 |
Optional Accessories
(a) Microprocessor Based PID Temp. Indicator- cum
controller In lieu of Digital controller
Oven Universal (Memmert Type)"altis"
These are sturdy double walled units
with outer chamber made of M.S. sheet duly enamel with inner made up of
anodized aluminium or S.S. sheet. The gap between inner and outer chamber is
filled with high grade glass wool to avoid thermal losses. Beaded heating
elements are placed in ribs, at bottom and sides. Inner chamber is provided
with ribs for adjusting perforated shelves to convenient height. Temperature
is controlled by imported hydraulic type capillary thermostat from 500C to
2500C ± 10C. An-L shaped prismatic thermometer is fitted to the unit
for reading the chamber temperature. Air ventilators are also provided on
the sides of the unit. To work on 220/230 volts A.C.
 |
Inner Camber Size |
Cap |
(a) 300 x 300 x 300 mm |
28 ltrs. |
(b) 355 x 355 x 355 mm |
45 ltrs. |
(c) 455 x 455 x 455 mm |
95 ltrs. |
(d) 455 x 455 x 605 mm |
125 ltrs. |
(e) 605 x 605 x 605 mm |
224 ltrs. |
(f) 605 x 455 x 910 mm |
252 ltrs. |
(g) 605 x 605 x 910 mm |
336 ltrs. |
|
 |
Optional Accessories
(a) Air Circulation fan can also be provided at an
extra cost
(b) Mechanical timer (2 Hrs) at an extra cost
(c) Microprocessor based PID temp. Controller-cum-indicator instead of
Thermostat
(d) Digital Timer of 1 hour can be Provided.
Bacteriological Incubator (Memmert Type) "altis"
These are sturdy double walled units
with outer chamber made of M.S. sheet duly enamel painted with inner made up
of anodized aluminium or S.S. sheet. The gap between inner and outer chamber
is filled with high grade glass wool to avoid thermal losses. Beaded heating
elements are placed in ribs, at bottom and sides. Inner chamber is provided
with ribs for adjusting perforated shelves to convenient height. The door is
fitted with glass viewing window to facilitate inspection of sample without
disturbing the test temperature. Temperature is controlled by "EGO"
/ "JUMO" GERMAN hydraulic type capillary thermostat from ambient
to 700C ± 0.50C An L-shaped prismatic thermometer is fitted to unit for
reading the chamber temperature. Air ventilators are also provided on the
sides of unit. To work on 220/230 volts A.C. Supply
 |
Inner Camber Size (WxDxH) |
Cap |
(a) 300 x 300 x 300 mm |
28 ltrs. |
(b) 355 x 355 x 355 mm |
45 ltrs. |
(c) 455 x 455 x 455 mm |
95 ltrs. |
(d) 455 x 455 x 605 mm |
125 ltrs. |
(e) 605 x 605 x 605 mm |
224 ltrs. |
(f) 605 x 455 x 910 mm |
252 ltrs. |
(g) 605 x 605 x 910 mm |
336 ltrs. |
|
 |
Optional Accessories
(a) Air Circulation fan, (Essential for (e), (f) and
(g)
(b) Mechanical timer
(c) Volt meter
(d) Micro Processor Based PID temp. Controller-cum indicator
(e) Digital Timer
Industrial Drying Oven "altis"

|
It is a double walled unit mounted on
a sturdy iron frame, Inner and outer made up of heavy M.S. sheet, duly
hammer tone painted and inner with high temperature Aluminium paint. The gap
between two walls is filled high grade glass wool to minimise thermal loss.
Brackets to support the heavily drying trays at adjustable height are
provided on the sided of inner walls. Heating is brought about by strip type
air heaters, and each heater in an independent unit which can be easily
replaced in event of failure. Temperature range from 500C to 2500C is
controlled by digital temp controller-cum-indicator with an accuracy of ±
50C the inner chamber temperature. Ventilation is provided with adjustable
opening at the top to exhaust the fumes of vapors produced during
processing. Unit is supplied with 3 shelves and extra shelves can be
supplied at extra cost. A heavy duty 'V' belt driven motor suitable capacity
provides forced air circulation so as to ensure uniform heating throughout
the inner chamber. A separate control panel is fitted to chamber with
individual control for ON/OFF. Air circulating fan and thermostat. To work
400/440 Volts A.C. supply only.
 |
Size Inside Chammber |
Load |
No. of Tray |
(a) 900 x 600 x 600 mm |
6.0 KW |
12 |
(b) 900 x 900 x 900 mm |
7.0 KW |
18 |
(c) 1200 x 900 x 900 mm |
7.0 KW |
24 |
(d) 1500 x 900 x 900 mm |
10.0 KW |
30 |
(e) 1800 x 900 x 600 mm |
10.0 KW |
36 |
(f) 1800 x 900 x 900 mm |
18.0 KW |
48 |
(g) 2400 x 900 x 900 mm |
24.0 KW |
60 |
(h) 2400 x 1200 x 900 mm |
30.0 KW |
96 |
|
 |
Tray Dryer "altis"
Details same as DE-111 but supplied
with aluminium drying trays. Number of trys supplied with the unit depending
upon its wise and as mentioned below.
 |
Size (W X D X H) |
Tray Capacity |
Load |
(a) 43 x 84 x 65 cm |
8 |
3 KW |
(b) 43 x 84 x 91 cm |
12 |
5 KW |
(c) 91 x 84 x 91 cm |
24 |
8 KW |
(d) 85 x 127 x 145 cm |
48 |
12 KW |
(e) 96 x 170 x 170 cm |
96 |
22 KW |
(f) 203 x 183 x 193 cm |
192 |
38 KW |
|
 |
Optional Accessories
(a) Additional Standard Tray of size 800x400x30 mm,
if required
(b) Digital Temperature Indicator-cum-Controller
(c) Automatic 0-24 minute "IMPORTED" Timer
(d) Automatic 0-120 minute" GERMAN" Timer